This document goes over how to set the logging for the CLRIP, XiEvents, XiService, and XiSpooler to rotate on a daily basis.

 

CLRIP.exe:

  1. Close Navigator Server
  2. Make sure that all processes associated with the server have closed.
     (CLRIP, XiEvents, XiService, XiSpooler, XiSpooler, XFDebug)
  3. Browse to the clrip.ini file located at the address below
     (C:\Users\”USER”\AppData\Roaming\Xitron\NX)
  4. Open the clrip.ini file in a text editor like Notepad or Notepad++
  5. Change RotateLogs=0 to RotateLogs=1
  6. Save and Close
  7. Restart the Server

 

The clrip.log will now rotate on a daily basis and be archived in the following location. The clrip.log will contain the date and time of when the log was saved.

 

C:\Navigator\Renderers\NR_1\SW\Archived Logs

 

Example log name: clrip07292022143612.log

 

XiEvents.exe:

  1. Close Navigator Server
  2. Make sure that all processes associated with the server have closed.
     (CLRIP, XiEvents, XiService, XiSpooler, XiSpooler, XFDebug)
  3. Browse to the XiEvents.ini file located at the address below
     (C:\Users\”USER”\AppData\Roaming\Xitron\NX)
  4. Open the XiEvents.ini file in a text editor like Notepad or Notepad++
  5. Change RotateLogs=0 to RotateLogs=1
  6. Save and Close
  7. Restart the Server

 

The XiEvents.log will now rotate on a daily basis and be archived in the following location. The XiEvents.log will contain the date and time of when the log was saved.

 

C:\Navigator\ Navigator\Utilities\Logs\Archived Logs

 

Example log name: XiEvents07292022143718.log

 

XiService.exe:

  1. Close Navigator Server
  2. Make sure that all processes associated with the server have closed.
     (CLRIP, XiEvents, XiService, XiSpooler, XiSpooler, XFDebug)
  3. Browse to the XiService.ini file located at the address below
     (C:\Users\”USER”\AppData\Roaming\Xitron\NX)
  4. Open the XiService.ini file in a text editor like Notepad or Notepad++
  5. Change RotateLogs=0 to RotateLogs=1
  6. Save and Close
  7. Restart the Server

 

The XiService.log will now rotate on a daily basis and be archived in the following location. The XiService.log will contain the date and time of when the log was saved.

 

C:\Navigator\ Navigator\Utilities\Logs\Archived Logs

 

Example log name: XiService07292022143825.log

 

XiSpooler.exe:

  1. Close Navigator Server
  2. Make sure that all processes associated with the server have closed.
     (CLRIP, XiEvents, XiService, XiSpooler, XiSpooler, XFDebug)
  3. Browse to the XiSpooler.ini file located at the address below
     (C:\Users\”USER”\AppData\Roaming\Xitron\NX)
  4. Open the XiSpooler.ini file in a text editor like Notepad or Notepad++
  5. Change RotateLogs=0 to RotateLogs=1
  6. Save and Close
  7. Restart the Server

 

The XiSpooler.log will now rotate on a daily basis and be archived in the following location. The XiSpooler.log will contain the date and time of when the log was saved.

 

C:\Navigator\ Navigator\Utilities\Logs\Archived Logs

 

Example log name: XiSpooler07292022144642.log

 

 